REGENERATIVE DC ELECTRONIC LOAD MODEL 63700 SERIES
- Rated power: 6kW, 12kW, 18kW
- Voltage range: 600V, 1,200V, 1,800V
- Current range: Up to 120A
- High Power Density: 18kW @ 3U height
- Energy recovery efficiency: Up to 93%
REGENERATIVE AC ELECTRONIC LOAD MODEL 63800R SERIES
- Rated power: 9kVA, 12kVA, 15kVA
- Rated current: 87Arms, 96Arms, 105Arms
- Voltage range: 30Vrms~350Vrms
Regenerative Battery Pack Test System Model 17040E
- High power test equipment Voltage range: 100~1700V Current range: 0~4800A Power range: 0~1.2MW
- High accuracy current/voltage measurement 0.02% r.d.g. + 0.02% r.n.g. (0.05% of r.n.g.)
- Data recovery protection (after power failure)
PRS-300 PRECISION PROGRAMMABLE RESISTANCE DECADE
- Resistance Range: 0.1 Ω to 20 MΩ
- Precision Lab Grade Accuracy 70 ppm + 1 mΩ
- Resolution: 1 μΩ ( 0.000 001 Ω) or 6 digits
- To further improve accuracy to <20 ppm, for no additional cost, see the PRS-DMM
- Programmable resistor with USB interface and Labview drivers
- 5 year warranty
HPRS-HIPOT-LOAD (FLUKE 5320A-LOAD HIPOT REPLACEMENT) HIPOT CURRENT CALIBRATION LOAD RESISTORS
- 8 Resistances from 10 kΩ to 5 MΩ standard
- Standard accuracy: ±10% at 23°C
- Power rating : up to 300 W at 100 kΩ
- Voltage rating: 1,400 to 5,500 V depending upon resistance value
- Continuous operation at rated power
- Kel-F washers on all terminals for low leakage current and high dielectric strength
- Custom values available for AR and QuadTech/Chroma hipot testers
ESI RS925D RESISTANCE DECADE
- High accuracy – 20 ppm + 0.5 mΩ
- High stability – 20 ppm + 0.5 mΩ
- Resistance from 10 mΩ to 1.1 MΩ
- 20 μΩ resolution
- Precise fixed minimum resistance
- Hermetically sealed, low inductance resistors
- The first 4 decades can be individually trimmed for increase accuracy
ESI / TEGAM DB62 DECADE RESISTOR
- Precision accuracy of ±(0.01% + 2 mΩ)
- Resistance range from 0.01 Ω to 11.1111 MΩ
- 4 models available, each covering six decades
- High-performance solid silver-alloy contacts
- Low zero resistance < 6mΩ
ESI SR1050 SERIES 1M & 10 M RESISTANCE TRANSFER STANDARD
- Resistance Values 1 MΩ & 10 MΩ
- Initial Accuracy… ± 25 or 30 ppm of nominal value matched within 10 ppm
- Transfer Accuracy… ± 2 ppm (Typical Short-term Repeatability)
- Calibration Accuracy… ± 10 or 15 ppm
ESI SR1010 RESISTANCE TRANSFER STANDARD
- Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
- Initial Accuracy… ± 20PPM of nominal value matched within 10PPM
- Transfer Accuracy… ± (1PPM + 0.1uΩ at parallel value) for 100:1
- Transfer Accuracy… ± (1PPM + 1uΩ at series parallel value) for 10:1
- Long Term Accuracy… ± 50PPM of nominal value
- Calibration Accuracy… ± 10PPM