Product Name

Model Number

Brand

Category

REGENERATIVE DC ELECTRONIC LOAD MODEL 63700 SERIES

  • Rated power: 6kW, 12kW, 18kW
  • Voltage range: 600V, 1,200V, 1,800V
  • Current range: Up to 120A
  • High Power Density: 18kW @ 3U height
  • Energy recovery efficiency: Up to 93%

REGENERATIVE AC ELECTRONIC LOAD MODEL 63800R SERIES

  • Rated power: 9kVA, 12kVA, 15kVA
  • Rated current: 87Arms, 96Arms, 105Arms
  • Voltage range: 30Vrms~350Vrms

Regenerative Battery Pack Test System Model 17040E

  • High power test equipment Voltage range: 100~1700V Current range: 0~4800A Power range: 0~1.2MW
  • High accuracy current/voltage measurement 0.02% r.d.g. + 0.02% r.n.g. (0.05% of r.n.g.)
  • Data recovery protection (after power failure)

PRS-300 PRECISION PROGRAMMABLE RESISTANCE DECADE

  • Resistance Range: 0.1 Ω to 20 MΩ
  • Precision Lab Grade Accuracy 70 ppm + 1 mΩ
  • Resolution: 1 μΩ ( 0.000 001 Ω) or 6 digits
  • To further improve accuracy to <20 ppm, for no additional cost, see the PRS-DMM
  • Programmable resistor with USB interface and Labview drivers
  • 5 year warranty

HPRS-HIPOT-LOAD (FLUKE 5320A-LOAD HIPOT REPLACEMENT) HIPOT CURRENT CALIBRATION LOAD RESISTORS

  • 8 Resistances from 10 kΩ to 5 MΩ standard
  • Standard accuracy: ±10% at 23°C
  • Power rating : up to 300 W at 100 kΩ
  • Voltage rating: 1,400 to 5,500 V depending upon resistance value
  • Continuous operation at rated power
  • Kel-F washers on all terminals for low leakage current and high dielectric strength
  • Custom values available for AR and QuadTech/Chroma hipot testers

ESI RS925D RESISTANCE DECADE

  • High accuracy – 20 ppm + 0.5 mΩ
  • High stability – 20 ppm + 0.5 mΩ
  • Resistance from 10 mΩ to 1.1 MΩ
  • 20 μΩ resolution
  • Precise fixed minimum resistance
  • Hermetically sealed, low inductance resistors
  • The first 4 decades can be individually trimmed for increase accuracy

ESI / TEGAM DB62 DECADE RESISTOR

  • Precision accuracy of ±(0.01% + 2 mΩ)
  • Resistance range from 0.01 Ω to 11.1111 MΩ
  • 4 models available, each covering six decades
  • High-performance solid silver-alloy contacts
  • Low zero resistance < 6mΩ

ESI SR1050 SERIES 1M & 10 M RESISTANCE TRANSFER STANDARD

  • Resistance Values 1 MΩ & 10 MΩ
  • Initial Accuracy… ± 25 or 30 ppm of nominal value matched within 10 ppm
  • Transfer Accuracy… ± 2 ppm (Typical Short-term Repeatability)
  • Calibration Accuracy… ± 10 or 15 ppm

ESI SR1010 RESISTANCE TRANSFER STANDARD

  • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
  • Initial Accuracy… ± 20PPM of nominal value matched within 10PPM
  • Transfer Accuracy… ± (1PPM + 0.1uΩ at parallel value) for 100:1
  • Transfer Accuracy… ± (1PPM + 1uΩ at series parallel value) for 10:1
  • Long Term Accuracy… ± 50PPM of nominal value
  • Calibration Accuracy… ± 10PPM