Transformer Test System / Component Analyzer Model 3250/3252/3302

Key Features

  • Test frequency: 20Hz~200kHz/1MHz, 0.02% accuracy
  • Basic accuracy: 0.1%
  • Different output impedance modes, measurement results are compatible with other well-known LCR meters
  • Enhanced Turn Ratio measurement accuracy for low permeability core
  • Fast Inductance/ Turn Ratio measurement speed up to 80 meas./sec
  • Fast DCR measurement speed up to 50 meas./sec
  • Graphical and tabular display of swept frequency, voltage current and bias current measurements (3252/3302)
  • Build-in 8mA bias for RJ45 transmission transformer saturation condition (option)
  • Leakage inductance 100 bin sorting and balance of leakage inductance for TV inverter transformer
  • ALC (Auto Level Compensation) function for MLCC measurement (3252/3302)
  • Test fixture residual capacitance compensation for transformer inductance measurement
  • 1320 Bias Current Source directly control capability (3252/3302)
  • 320×240 dot-matrix LCD display
  • Support versatile standard and custom-design test jigs
  • Four-terminal test for accurate, stable DCR, inductance and turn ratio measurements
  • Built-in comparator; 10 bin sorting with counter capability (3252/3302)
  • Lk standard value with Lx measure value
  • 4M SRAM memory card, for setup back-up between units
  • Standard RS-232, Handler, and Printer Interface, option GPIB Interface for LCR function only
  • 15 internal instrument setups for store/recall capability

Description

The 3250/3252/3302 Transformer Test System are the precision test systems, designed for transformer production line or incoming/ outgoing inspection in quality control process, with high stability and high reliability.

The 3250/3252 provide 20Hz-200kHz test frequencies, and 3302 provides 20Hz-1MHz test frequencies. In addition to transformer scanning test function, the 3252/3302 have LCR Meter function. In test items, The 3250/3252/3302 cover most of transformer’s low-voltage test parameters which include primary test parameters as Inductance, Leakage Inductance, Turns-Ratio, DC resistance, Impedance, and Capacitance (between windings) etc.; secondary test parameters as Quality Factor and ESR etc.; and pin-short test function. High-speed digital sampling measurement technology combined with scanning test fixture (A132501) design, improve low-efficiency transformer inspection to be more accurate and faster.

The 3250/3252/3302 even provide several output impedance selection to solve inductance measurement error problem caused by different test current caused by different output impedance provided by different LCR Meters. And, equivalent turns-ratio calculated from measured inductance of windings is also provided to improve turns-ratio measurement error problem caused by large leakage magnetic flux in transformer with low permeability magnetic core.

In addition to transformer scanning test function, the 3252/3302 have LCR Meter function, can be used in component incoming/outgoing inspection, analysis and automatic production line.

Related Products

RF LCR METER MODEL 11090-030

  • Wide range of test frequencies: 100kHz~300MHz
  • Fast measurement speed: 0.5 (ms)
  • Various functions:
    – Calibration/compensation status guidance
    – Contact check for magnetic components through Rdc
    – Multi-parameter comparison and bin-sorting
    – Multi-point (~401 points) test and curve drawing
    – Clear and guided operation
  • Fast-operating SMD test fixture (patent TW M621845 / CN 216013502U)

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Leakage Current/IR Meter (CLC/IR Meter) Model 11200

  • DC voltage: 1.0V~650V / 800V
  • Charge current: 0.5mA~500mA
  • Leakage current measurement: 0.001uA~20.00mA
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Test System Model 1820

  • High frequency sine wave current: 1kHz~20kHz, 10kHz~200kHz
  • DC bias voltage: 5000V max.
  • Capacitor endurance & temperature rising test

Battery Cell Insulation Tester Model 11210

  • Test voltage: up to 1KV(dc)
  • Charge current: 50mA max.
  • Wide range of Leakage Current (LC) measurement (10pA ~ 20mA)
  • Automatic test with sequence: charge-dwell-measure-discharge

Electrical Double Layer Capacitor ATS (EDLC ATS) Model 8801

  • Measurement function: C, IR, and ESR
  • 10ch scanner for reducing test time
  • Windows based software with open architecture

Component Test Scanner Model 13001

  • Optional 40ch scan module and slave unit
  • Support 8 slots for module plug-in, up to 320ch per unit
  • Support 8 slave unit for connecting to master unit
  • Standard RS-232, GPIB, and USB I/F