Milliohm Meter Model 16502

Key Features

  • Basic accuracy: 0.05%
  • Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement
  • DC test current output mode is used to fasten measurement speed for inductive DUT
  • Dry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mV
  • Temperature correction (TC function) regardless of material or temperature
  • Useful temperature conversion function for motor/ coil evaluation
  • 4 channels R scan with balance check function for fan motor (combined with A165017 option)
  • 0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolution
  • Standard RS-232 interface
  • Optional GPIB & Handler interface
  • Bin-sorting function
  • Comparator and pass/fail alarming beeper function
  • Large LCD display (240 x 64 dot-matrix)
  • Friendly user interface
  • LabView® Driver

Description

The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enabling the Chroma 16502 can to be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.

Using the A165014 Temperature Compensation Card with A165015 PT100 Temperature Probe, resistance values measured at ambient temperature can be corrected by applying a thermal coefficient so that the display shows the corresponding resistance values at any other temperature with temperature correction function. Temperature increase (Δt) is obtained and di splayed by converting resistance measurements and ambient temperature with convenient temperature conversion function. This function is especially useful for verifying motor windings or coils, where the maximum temperature increase needs to be determined when current is applied.

Pulsed ± function application includes power choke, switch/Relay contract, multi-braided twisted wires, metallic foil or conductive material, thermo-sensitive material (fuse, thermistor sensor) etc. Dry Circuit function application includes switch /relay contract, thermo-sensitive material (fuse, thermistor sensor) etc. DC+ function app lication includes high inductance DUT, like primary of transformer (multi-turn) measurement with Measurement Delay Function to avoid the test current not produced that effect by high inductance DUT during test period.

Standard RS-232 interface, optional GPIB & Handler inter face, high speed and stable measurement capabilities enable the Chroma 16502 can be used for both component evaluation on the production line and milliohm measurement for bench-top applications.

Related Products

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Leakage Current/IR Meter (CLC/IR Meter) Model 11200

  • DC voltage: 1.0V~650V / 800V
  • Charge current: 0.5mA~500mA
  • Leakage current measurement: 0.001uA~20.00mA
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Test System Model 1820

  • High frequency sine wave current: 1kHz~20kHz, 10kHz~200kHz
  • DC bias voltage: 5000V max.
  • Capacitor endurance & temperature rising test

Battery Cell Insulation Tester Model 11210

  • Test voltage: up to 1KV(dc)
  • Charge current: 50mA max.
  • Wide range of Leakage Current (LC) measurement (10pA ~ 20mA)
  • Automatic test with sequence: charge-dwell-measure-discharge

Electrical Double Layer Capacitor ATS (EDLC ATS) Model 8801

  • Measurement function: C, IR, and ESR
  • 10ch scanner for reducing test time
  • Windows based software with open architecture

Component Test Scanner Model 13001

  • Optional 40ch scan module and slave unit
  • Support 8 slots for module plug-in, up to 320ch per unit
  • Support 8 slave unit for connecting to master unit
  • Standard RS-232, GPIB, and USB I/F

Programmable HF AC Tester Model 11802/11803/11805/11890/11891

  • Test frequency: 20kHz~200kHz (11802/11890/11891) / 10kHz~200kHz (11805) / 20kHz~1MHz (11803)
  • Maximum output power: 500VA (11802/11890/11891) / 800VA (11803) / 1kVA (11805)
  • Optional voltage / current step-up modules
  • Standard RS-485 I/F

Component Automatic Test System Model 8800

  • Support instruments with GPIB, RS-232, or RS-485 I/F
  • Windows based software with open architecture
  • Test items and test programs editabl