RTD SERIES – PRECISION RTD SIMULATOR

Key Features

  • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
  • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
  • Resolution: 1 mΩ (0.0025 ºC for PT 100)
  • Stability 0.0002% for 24 hours; 0.001% for 12 months
  • PT100 to Resistance Chart with 0.1 mΩ Resolution
  • 4 models available
  • Unlike other decade resistors RTD Simulator series has no “zero” or contact resistance to account for
  • Designed for DIN PT-100, PT-1000, ANSI, PT-50 and NI-120 systems

Description

The RTD Series Precision RTD (Resistance Temperature Detector) Simulator provides a very broad-range of absolute resistance values that calibrate RTD’s and thermocouples. Thermocouples present a resistance that depends on the temperature.

The RTD simulator effectively replaces an RTD to test, analyze, and calibrate RTD measuring systems. The RTD Series simulator is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.

The special design of the RTD Series provides absolute accuracy, and requires no zero resistance subtraction from any setting Special design of the RTD virtually eliminate zero resistance and switch contact variations, providing the specified absolute accuracy over the entire range.

The RTD Simulator series is available in 4 models that vary by resistance range and precision. The RTD-Z is the choice for the most demanding RTD Simulation applications. These units have a 50 ppm (0.005%) absolute accuracy. The RTD-X series is more cost effective but still quite precise with a 100 ppm (0.01%) absolute accuracy

All RTD Simulator models have 6 decades. The units either have a 1 mΩ resolution with a max resistance of 1,000 Ω, which is best for PT-100 or a 10 mΩ resolution with a max resistance of 10,000 Ω, which is best for PT-1000’s. The minimum resistance, or the lowest you can dial the unit, for all models is 10 Ω.

Related Products

PRS-300 PRECISION PROGRAMMABLE RESISTANCE DECADE

  • Resistance Range: 0.1 Ω to 20 MΩ
  • Precision Lab Grade Accuracy 70 ppm + 1 mΩ
  • Resolution: 1 μΩ ( 0.000 001 Ω) or 6 digits
  • To further improve accuracy to <20 ppm, for no additional cost, see the PRS-DMM
  • Programmable resistor with USB interface and Labview drivers
  • 5 year warranty

HPRS-HIPOT-LOAD (FLUKE 5320A-LOAD HIPOT REPLACEMENT) HIPOT CURRENT CALIBRATION LOAD RESISTORS

  • 8 Resistances from 10 kΩ to 5 MΩ standard
  • Standard accuracy: ±10% at 23°C
  • Power rating : up to 300 W at 100 kΩ
  • Voltage rating: 1,400 to 5,500 V depending upon resistance value
  • Continuous operation at rated power
  • Kel-F washers on all terminals for low leakage current and high dielectric strength
  • Custom values available for AR and QuadTech/Chroma hipot testers

ESI RS925D RESISTANCE DECADE

  • High accuracy – 20 ppm + 0.5 mΩ
  • High stability – 20 ppm + 0.5 mΩ
  • Resistance from 10 mΩ to 1.1 MΩ
  • 20 μΩ resolution
  • Precise fixed minimum resistance
  • Hermetically sealed, low inductance resistors
  • The first 4 decades can be individually trimmed for increase accuracy

ESI / TEGAM DB62 DECADE RESISTOR

  • Precision accuracy of ±(0.01% + 2 mΩ)
  • Resistance range from 0.01 Ω to 11.1111 MΩ
  • 4 models available, each covering six decades
  • High-performance solid silver-alloy contacts
  • Low zero resistance < 6mΩ

ESI SR1050 SERIES 1M & 10 M RESISTANCE TRANSFER STANDARD

  • Resistance Values 1 MΩ & 10 MΩ
  • Initial Accuracy… ± 25 or 30 ppm of nominal value matched within 10 ppm
  • Transfer Accuracy… ± 2 ppm (Typical Short-term Repeatability)
  • Calibration Accuracy… ± 10 or 15 ppm

ESI SR1010 RESISTANCE TRANSFER STANDARD

  • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
  • Initial Accuracy… ± 20PPM of nominal value matched within 10PPM
  • Transfer Accuracy… ± (1PPM + 0.1uΩ at parallel value) for 100:1
  • Transfer Accuracy… ± (1PPM + 1uΩ at series parallel value) for 10:1
  • Long Term Accuracy… ± 50PPM of nominal value
  • Calibration Accuracy… ± 10PPM

PRS-200 SERIES PROGRAMMABLE RESISTANCE DECADE BOX

  • IEEE, RS232 or Ethernet Programmable Decade Resistor
  • Wide range and resolution: 100 mΩ to 100 M&Omega with 1 mΩ resolution
  • Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
  • Special RTD and custom configurations
  • Dual / Combo rackmount models ( examples: Resistance & Capacitance or Resistance & Inductance)

ESI SR1030 SERIES OIL IMMERSED TRANSFER STANDARD

  • Resistance Values of 1 Ω – 100 kΩ
  • Initial Accuracy… ± 20 PPM of nominal value matched within 10 PPM
  • Transfer Accuracy… ± (1 PPM + 0.1uΩ at parallel value) for 100:1
  • Long Term Accuracy… ± 50 PPM of nominal value
  • Calibration Accuracy… ± 10 PPM