Ripple Current Tester Model 11800/11801/11810

Key Features

  • Digital constant current output and constant peak voltage output control function
  • Four terminal contact test jig design, ensure accurate monitoring of voltage dropped on capacitors under test (patent pending)
  • Paired cooper-foil wiring test cable to reduce voltage drop on the current driving loop and to ensure accurate monitoring of ac level dropped on capacitors under test (patent pending)
  • 0-500 V DC bias voltage source, 0.3% basic accuracy
  • 0.01~30A, 100Hz/120Hz/400Hz/1kHz AC ripple current source, (±0.5% reading+0.1% of range) basic accuracy (Model 11800)
  • 0.01~10A, 20kHz~100kHz AC ripple current source, 2% basic accuracy (Model 11801)
  • 0.03~10A, 20kHz~1MHz AC ripple current source (Model 11810)
  • Monitoring software (option) for multiple Ripple Current Testers
  • Lower power consumption and lower electricity cost
  • Large LCD display (320 x 240 dot-matrix)
  • Alarm for indicating of normal or abnormal test termination, Tested time will be recorded if the test is terminated abnormally. An automatic discharge is always performed after test termination
  • Standard RS485 interface is provided for computer monitoring
  • Optional 20-fixtures Series or Parallel test jigs
  • Digital timer inside
  • CE marking (Model 11800/11801)

Description

The Chroma 11800/11801/11810 Ripple Current Tester is a precision tester designed for electrolytic capacitors load life testing. Provides constant ripple current output and constant peak voltage (Vpeak = Vdc + Vac_peak) output digital control function. Let load life testing for electrolytic capacitors becomes easier and more reliable. And, The Chroma 11800/11801/11810 use excellent output amplifier design technology to reduce power consumption and internal temperature rising. For long time testing requirement, it can reduce electricity cost and perform high stability. The Chroma 11800/11801/11810 is a just right test solution for electrolytic quality evaluation.

Related Products

RF LCR METER MODEL 11090-030

  • Wide range of test frequencies: 100kHz~300MHz
  • Fast measurement speed: 0.5 (ms)
  • Various functions:
    – Calibration/compensation status guidance
    – Contact check for magnetic components through Rdc
    – Multi-parameter comparison and bin-sorting
    – Multi-point (~401 points) test and curve drawing
    – Clear and guided operation
  • Fast-operating SMD test fixture (patent TW M621845 / CN 216013502U)

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Leakage Current/IR Meter (CLC/IR Meter) Model 11200

  • DC voltage: 1.0V~650V / 800V
  • Charge current: 0.5mA~500mA
  • Leakage current measurement: 0.001uA~20.00mA
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Test System Model 1820

  • High frequency sine wave current: 1kHz~20kHz, 10kHz~200kHz
  • DC bias voltage: 5000V max.
  • Capacitor endurance & temperature rising test

Battery Cell Insulation Tester Model 11210

  • Test voltage: up to 1KV(dc)
  • Charge current: 50mA max.
  • Wide range of Leakage Current (LC) measurement (10pA ~ 20mA)
  • Automatic test with sequence: charge-dwell-measure-discharge

Electrical Double Layer Capacitor ATS (EDLC ATS) Model 8801

  • Measurement function: C, IR, and ESR
  • 10ch scanner for reducing test time
  • Windows based software with open architecture

Component Test Scanner Model 13001

  • Optional 40ch scan module and slave unit
  • Support 8 slots for module plug-in, up to 320ch per unit
  • Support 8 slave unit for connecting to master unit
  • Standard RS-232, GPIB, and USB I/F