Key Features

  • Test Parameter: L/C/R/Z/Y/DCR/Q/D/θ
  • Test Frequency:
    • 75kHZ~30MHz (11050-30M)
    • 1kHz~10MHz (11050)
    • 60Hz~5MHz (11050-5M)
  • Test Level: 10mV ~ 5V
  • Basic Accuracy: 0.1%
  • 7ms fast speed measurement
  • 3 output impedance modes
  • Test signal monitoring function
  • Compare & bin-sorting function
  • Open/short zeroing & load correction function
  • Detached measurement & display unit design
  • Standard Handler, RS-232C, USB storage & external bias current control interface
  • Optional Bias Current Source 0~5A/20A(100kHz~10MHz)
  • Optional GPIB or LAN interface

Description

The Chroma 11050 series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range from 75kHz~30MHz/1kHz~10MHz/60Hz~5MHz suitable for analyzing the components’ characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.

In addition to the excellent measurement features found in other Chroma LCR Meters, the 11050 series includes additional useful functions. It has 3 output impedance modes to satisfy demands of measuring and working with other instruments. The versatile digital display can be configured to best fit the current testing resolution; furthermore, the test signal monitoring function displays the voltage and current that is actually carried to the DUT. The timing settings of trigger delay, measure delay and average number of times allow the measurements to transfer seamlessly to an automated test environment providing accurate results within a limited testing time.

The detached design adopted by the Chroma 11050 series provides several advantages. Since test processing and the display use separate CPUs, the testing speed is increased and shorter test leads are needed when integrated into an automated test environment. Shorter test leads improve the accuracy of high frequency measurements.

Chroma’s 11050 series HF LCR Meter has multiple remote interface options. Handler and RS-232C remote interfaces come standard for software or hardware control of test conditions, measurement trigger, judge test results, and collect measured data. The standard USB port saves device settings and controls the output of an external DC bias current source. Optional GPIB and Ethernet remote interfaces are available as well for software control.

Due to the design of modern portable electronic communication devices with thin form factors and low power consumption, required frequency testing of power inductors is increasing. The equivalent series resistance of components has become a critical indicator to identify if it is good or bad. The buffer capacitor plays an important role for overall circuit reliability and must function properly under various voltage transient conditions; the equivalent series resistance must remain at a very low level when operated at high frequencies. The Chroma 11050 series is focused on testing passive components at high frequencies and with enhanced key measurement capabilities during R&D so that it simulates the user’s actual application as closely as possible. The increased accuracy of low impedance measurements demonstrates the usefulness of Chroma 11050 series in high frequency testing applications.

The Chroma 11050 series HF LCR Meter was designed with many enhancements and key features to make it the best choice to meet the demands of modern component characterization analysis and high speed testing for automated production line or incoming/outgoing inspection applications.

Related Products

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Leakage Current/IR Meter (CLC/IR Meter) Model 11200

  • DC voltage: 1.0V~650V / 800V
  • Charge current: 0.5mA~500mA
  • Leakage current measurement: 0.001uA~20.00mA
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Test System Model 1820

  • High frequency sine wave current: 1kHz~20kHz, 10kHz~200kHz
  • DC bias voltage: 5000V max.
  • Capacitor endurance & temperature rising test

Battery Cell Insulation Tester Model 11210

  • Test voltage: up to 1KV(dc)
  • Charge current: 50mA max.
  • Wide range of Leakage Current (LC) measurement (10pA ~ 20mA)
  • Automatic test with sequence: charge-dwell-measure-discharge

Electrical Double Layer Capacitor ATS (EDLC ATS) Model 8801

  • Measurement function: C, IR, and ESR
  • 10ch scanner for reducing test time
  • Windows based software with open architecture

Component Test Scanner Model 13001

  • Optional 40ch scan module and slave unit
  • Support 8 slots for module plug-in, up to 320ch per unit
  • Support 8 slave unit for connecting to master unit
  • Standard RS-232, GPIB, and USB I/F

Programmable HF AC Tester Model 11802/11803/11805/11890/11891

  • Test frequency: 20kHz~200kHz (11802/11890/11891) / 10kHz~200kHz (11805) / 20kHz~1MHz (11803)
  • Maximum output power: 500VA (11802/11890/11891) / 800VA (11803) / 1kVA (11805)
  • Optional voltage / current step-up modules