Electrolytic Capacitor Analyzer Model 13100

Key Features

  • C meter provides Z/C/D/Q/ESR parameters for test
  • Available 7 test frequencies from 100~100kHz for selection
  • 0.1% basic measurement accuracy
  • The thin-film withstand voltage results can be displayed in graph by converting them to an actual rising curve
  • CPK calculation function for 1000 capacitor test results that is convenient for analyzing the production capability
  • 320 x 240 dot-matrix LCD display
  • 200 sets of internal memories and 4M SRAM interface card for saving and recalling the parameter settings
  • Designed for100mΩ range with accuracy measurement up to 0.1mΩ
  • Non-Relay switch is built in. It is safe and reliable as the discharge circuit is close to the fixed power
  • Perform electric polarity test before charge to avoid the danger of explosion
  • Softpanel for leakage current data statistics analysis
  • Equipped with RS-232, printer and scanner controller interfaces
  • Meet the test regulation of EIAJ RC-2364A
  • A131001 scan box has four terminals designed for measuring accurate high frequency and low impedance

Description

The Chroma 13100 Electrolytic Capacitor Analyzer is a general measurement instrument designed for analyzing the features of electrolytic capacitor s. It has multiple functions that can be programmed based on the capacitor features by altering the settings to test metal oxidization thin-film withstand voltage, capacitor leakage current, capacitance, dissipation factor, impedance and equivalent serial resistance, etc.

Used with the special designed sequential switch test box A131001, it can complete the test for multiple capacitors or aluminum foil rapidly, accurately and simultaneously in a short time without changing any test wire.

The report printing function is capable of printing the test results correctly and completely; and the built-in data calculation function can compute the test data of the product instantly for CPK analysis. To avoid the inefficient calculation process done manually, a test software application is also available for you to create a quality report easily. It meets the EIAJ RC-2364A regulations for electrolytic capacitor test and is a test instrument of choice.

Chroma A131001 is a sequential switch test box of ten channels specially designed for Chroma 13100. Each test socket on the test box is implemented with Kelvin measurement, which is suitable for the precise measurement requirement for low impedance and low leakage current. With the SCAN function in 13100 it is able to control the C, D, Q, Z, ESR and LC tests for electrolytic capacitor to be done consecutively without switching the capacitor manually. This increases the test efficiency significantly as it costs only 1/10 of the original test time.

Related Products

RF LCR METER MODEL 11090-030

  • Wide range of test frequencies: 100kHz~300MHz
  • Fast measurement speed: 0.5 (ms)
  • Various functions:
    – Calibration/compensation status guidance
    – Contact check for magnetic components through Rdc
    – Multi-parameter comparison and bin-sorting
    – Multi-point (~401 points) test and curve drawing
    – Clear and guided operation
  • Fast-operating SMD test fixture (patent TW M621845 / CN 216013502U)

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Leakage Current/IR Meter (CLC/IR Meter) Model 11200

  • DC voltage: 1.0V~650V / 800V
  • Charge current: 0.5mA~500mA
  • Leakage current measurement: 0.001uA~20.00mA
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Test System Model 1820

  • High frequency sine wave current: 1kHz~20kHz, 10kHz~200kHz
  • DC bias voltage: 5000V max.
  • Capacitor endurance & temperature rising test

Battery Cell Insulation Tester Model 11210

  • Test voltage: up to 1KV(dc)
  • Charge current: 50mA max.
  • Wide range of Leakage Current (LC) measurement (10pA ~ 20mA)
  • Automatic test with sequence: charge-dwell-measure-discharge

Electrical Double Layer Capacitor ATS (EDLC ATS) Model 8801

  • Measurement function: C, IR, and ESR
  • 10ch scanner for reducing test time
  • Windows based software with open architecture

Component Test Scanner Model 13001

  • Optional 40ch scan module and slave unit
  • Support 8 slots for module plug-in, up to 320ch per unit
  • Support 8 slave unit for connecting to master unit
  • Standard RS-232, GPIB, and USB I/F