ESI SR1050 SERIES 1M & 10 M RESISTANCE TRANSFER STANDARD

Key Features

  • Resistance Values 1 MΩ & 10 MΩ
  • Initial Accuracy… ± 25 or 30 ppm of nominal value matched within 10 ppm
  • Transfer Accuracy… ± 2 ppm (Typical Short-term Repeatability)
  • Calibration Accuracy… ± 10 or 15 ppm

Description

For low resistance transfer standards, consider the esi SR1010 or SR1030

IET Labs continues to manufacture the SR1050 to the same exacting specs as esi/Tegam

Introduction
Each of the esi SR1050 transfer standards consists of 11 equal steps. These steps are available in increments of 1M Ω, (SR1050-1M) and 10M Ω, (SR1050-10M). The esi SR1050 provides a three terminal connection for each step or for a series of resistance steps. Specially designed lever switches separate each resistor from the others. This allows the standard to be configured in series, parallel, series-parallel, or separately without the use of external shorting bars.

Description
Precise transfer measurements up to 110 MΩ relative to a single 100 kΩ resistance standard can be obtained with the esi SR1050 High-Resistance Transfer Standards. The unit is available in two models: 1 MΩ and 10 MΩ resistance sections.

Based on a unique method for establishing known ratios, the esi SR1050 standard utilizes a transfer technique that consists of switching resistance sections in parallel, series or series-parallel sections. An outstanding design feature is a structure in which the only insulation leakage paths (other than those within each resistance section) are from the external terminals to ground. This eliminates insulation leakage errors in the transfer of calibration from one resistance level to another using three-terminal measurement techniques.

A specially designed lever switch provides a convenient means of switching into parallel and series parallel configuration without introducing insulation leakage errors. External shorting or paralleling bars are not necessary. Each resistance section consists of precision wire-wound resistors connected in series. The reduced heat concentration of the series connection improves the thermal characteristics of a resistance element with an already low temperature coefficient

Advantages of Transfer Standards
In order to perform calibrations with a high degree of accuracy, reference standards must be employed at every range or decade of the measuring or calibration instrumentation. Clearly, this can be difficult and costly since these standards must be highly stable and their precise values must be known with a high degree of certainty and sufficient resolution.

To minimize the cost and difficulty, more practical means of performing such calibrations is to use transfer standards.

If one has a single standard that is calibrated by a national laboratory, one can then compare the transfer standards to the certified standard by ratio techniques. See our Technical Applications section for a full tutorial. The Benefits of Using Transfer Standards

Related Products

PRS-300 PRECISION PROGRAMMABLE RESISTANCE DECADE

  • Resistance Range: 0.1 Ω to 20 MΩ
  • Precision Lab Grade Accuracy 70 ppm + 1 mΩ
  • Resolution: 1 μΩ ( 0.000 001 Ω) or 6 digits
  • To further improve accuracy to <20 ppm, for no additional cost, see the PRS-DMM
  • Programmable resistor with USB interface and Labview drivers
  • 5 year warranty

HPRS-HIPOT-LOAD (FLUKE 5320A-LOAD HIPOT REPLACEMENT) HIPOT CURRENT CALIBRATION LOAD RESISTORS

  • 8 Resistances from 10 kΩ to 5 MΩ standard
  • Standard accuracy: ±10% at 23°C
  • Power rating : up to 300 W at 100 kΩ
  • Voltage rating: 1,400 to 5,500 V depending upon resistance value
  • Continuous operation at rated power
  • Kel-F washers on all terminals for low leakage current and high dielectric strength
  • Custom values available for AR and QuadTech/Chroma hipot testers

ESI RS925D RESISTANCE DECADE

  • High accuracy – 20 ppm + 0.5 mΩ
  • High stability – 20 ppm + 0.5 mΩ
  • Resistance from 10 mΩ to 1.1 MΩ
  • 20 μΩ resolution
  • Precise fixed minimum resistance
  • Hermetically sealed, low inductance resistors
  • The first 4 decades can be individually trimmed for increase accuracy

ESI / TEGAM DB62 DECADE RESISTOR

  • Precision accuracy of ±(0.01% + 2 mΩ)
  • Resistance range from 0.01 Ω to 11.1111 MΩ
  • 4 models available, each covering six decades
  • High-performance solid silver-alloy contacts
  • Low zero resistance < 6mΩ

ESI SR1010 RESISTANCE TRANSFER STANDARD

  • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
  • Initial Accuracy… ± 20PPM of nominal value matched within 10PPM
  • Transfer Accuracy… ± (1PPM + 0.1uΩ at parallel value) for 100:1
  • Transfer Accuracy… ± (1PPM + 1uΩ at series parallel value) for 10:1
  • Long Term Accuracy… ± 50PPM of nominal value
  • Calibration Accuracy… ± 10PPM

PRS-200 SERIES PROGRAMMABLE RESISTANCE DECADE BOX

  • IEEE, RS232 or Ethernet Programmable Decade Resistor
  • Wide range and resolution: 100 mΩ to 100 M&Omega with 1 mΩ resolution
  • Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
  • Special RTD and custom configurations
  • Dual / Combo rackmount models ( examples: Resistance & Capacitance or Resistance & Inductance)

ESI SR1030 SERIES OIL IMMERSED TRANSFER STANDARD

  • Resistance Values of 1 Ω – 100 kΩ
  • Initial Accuracy… ± 20 PPM of nominal value matched within 10 PPM
  • Transfer Accuracy… ± (1 PPM + 0.1uΩ at parallel value) for 100:1
  • Long Term Accuracy… ± 50 PPM of nominal value
  • Calibration Accuracy… ± 10 PPM

RTD SERIES – PRECISION RTD SIMULATOR

  • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
  • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
  • Resolution: 1 mΩ (0.0025 ºC for PT 100)
  • Stability 0.0002% for 24 hours; 0.001% for 12 months