LCR Meter Model 11021/11021-L

Key Features

  • Test frequencies:
    • 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021)
    • 1kHz, 10kHz, 40kHz, 50kHz (11021-L)
  • Basic accuracy: 0.1% (11021), 0.2% (11021-L)
  • 0.1mΩ~99.99 MΩ measurement range, 4 1/2 digits resolution
  • Lower harmonic-distortion affection
  • Fast measurement speed (75ms)
  • Standard RS-232 interface
  • Optional GPIB & Handler interface
  • Programmable trigger delay time is convenient for measurement timing adjustment in automatic production
  • Bin-sorting function
  • Comparator and pass/fail alarming beeper function
  • Text mode 40×4 matrixes LCD display
  • Friendly user interface
  • Open/short zeroing
  • On-line fireware refreshable (via RS-232)
  • Input protection (1 Joule)

Description

The Chroma 11021/11021-L LCR Meter are the most cost-effective digital LCR Meter, provides 100Hz, 120Hz, 1kHz, and 10kHz test frequencies for the 11021 and 1kHz, 10kHz, 40kHz, 50kHz test frequencies for the 11021-L. Standard RS-232 interface, optional GPIB & Handler interface, high speed and stable measurement capabilities enable the Chroma 11021/11021-L can be used for both component evaluation on the production line and fundamental impedance testing for bench-top applications.

The Chroma 11021/11021-L use lower harmonic distortion phase-detection technology to reduce affection of measurement accuracy caused by hysteresis distortion in magnetic component or high dielectric-coefficient capacitor measurement, which is not provided in general low-end LCR Meters.

The 11021-L is the ideal selection for high frequency coil, core, choke, and etc. passive components incoming/outgoing material quality inspect and automatic production.

Related Products

RF LCR METER MODEL 11090-030

  • Wide range of test frequencies: 100kHz~300MHz
  • Fast measurement speed: 0.5 (ms)
  • Various functions:
    – Calibration/compensation status guidance
    – Contact check for magnetic components through Rdc
    – Multi-parameter comparison and bin-sorting
    – Multi-point (~401 points) test and curve drawing
    – Clear and guided operation
  • Fast-operating SMD test fixture (patent TW M621845 / CN 216013502U)

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Milliohm Meter Model 16502

  • Test signal: DC / pulsed
  • Basic accuracy: 0.05%
  • Measurement time: 65ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Leakage Current/IR Meter (CLC/IR Meter) Model 11200

  • DC voltage: 1.0V~650V / 800V
  • Charge current: 0.5mA~500mA
  • Leakage current measurement: 0.001uA~20.00mA
  • Standard RS-232 I/F, optional GPIB & Handler I/F

Capacitor Test System Model 1820

  • High frequency sine wave current: 1kHz~20kHz, 10kHz~200kHz
  • DC bias voltage: 5000V max.
  • Capacitor endurance & temperature rising test

Battery Cell Insulation Tester Model 11210

  • Test voltage: up to 1KV(dc)
  • Charge current: 50mA max.
  • Wide range of Leakage Current (LC) measurement (10pA ~ 20mA)
  • Automatic test with sequence: charge-dwell-measure-discharge

Electrical Double Layer Capacitor ATS (EDLC ATS) Model 8801

  • Measurement function: C, IR, and ESR
  • 10ch scanner for reducing test time
  • Windows based software with open architecture

Component Test Scanner Model 13001

  • Optional 40ch scan module and slave unit
  • Support 8 slots for module plug-in, up to 320ch per unit
  • Support 8 slave unit for connecting to master unit
  • Standard RS-232, GPIB, and USB I/F