Impulsing Winding Tester Model 19305 Series

Key Features

  • High impulse test sampling rate (200MHz),10bits
  • 6kV impulse voltage test
  • Breakdown voltage analysis function
  • High speed test
  • 10 channels output (19305-10)
  • Support max. 40 channels scanning test
  • Traditional Chinese, Simplified Chinese, English user interface
  • USB port for storing waveform & screen capture
  • Graphical color display
  • Standard LAN,USB and RS232 interfaces

Description

The Chroma 19305 series Impulse Winding Tester included with one channel(19305) and 10 channels output (19305-10), the 19305 series has 6kV impulse voltage and 200MHz high speed sampling rate to improve sensitivity of discharge detection. To test more than 10uH, the built-in Area Size Comparison, Differential Area Comparison, FLUTTER value and LAPLACIAN value functions are able to inspect the coils for poor coil insulation.

The inspection of winding components includes electrical characteristics and safety withstand voltage tests. Commonly poor insulation of coils is the root for causing layer short and output pin short-circuited during usage. The reason could result from bad initial design, poor process or deterioration of insulating materials; therefore, adding the coil layer short test to winding components has its necessity.

The impulse winding test is to impose a non-destructive, high speed and low energy voltage impulse on the DUT (Device Under Test) to analyze/compare the equivalent waveform of yield and defect products for good and no good judgment. The main function of impulse winding test is to discover the potential defects such as layer short, corona or partial discharge that is difficult to find in wound components in early phase.

The Chroma 19305 series is an equipment specifically designed for tes ting winding components utilizing a high voltage charged micro capacitor (low test energy) and coil under test to form an RLC parallel resonant. Analyzing the oscillation decayed waveform via a high speed and sophisticated sampling process technique can successfully detect the coils with poor insulation. Analyzer can perform impulse tests on wound components like motors, transformers wound products. Not only reliable quality but also efficient product control would be obtained when implementing it to quality verification by wound component test.

The Chroma 19305-10 can providing maximum 10 channels output for multichannel scanning tests to save time and labor cos t s in the manufacturers.

Related Products

Hipot Tester Model 19070 Series

  • Economy type
  • 3 In 1 (ACV/DCV/IR Test)

Wound Component EST Analyzer Model 19036

  • 5 in 1 composite analyzer scanner (ACW/DCW/IR/IWT/DCR)
  • Hi-pot test (5kVac / 6kVdc, HSCC, 500 VA output)
  • 5kV Insulation Resistance test (IR)
  • Impulse Winding Test (IWT)

Hipot Analyzer Model 19055/19055-C

  • Hipot test
    ACW 5kV/100mA
    DCW 6kV/25mA
  • Insulation Resistance test
    5kVmax
    1MΩ~50GΩ
  • 500VA output

Hipot Calibrator Model 9102

  • Adequate for versatile testers
  • Precise designed standard calibration kit
  • Stable & accurate calibration equipment

Impulsing Winding Tester Model 19301A

  • Wide range inductance test application(0.1uH~100uH).
  • Impulse Winding Test high sampling rate(200MHz).
  • Contact check & test voltage compensation by measured inductance.
  • B.D.V function(BreakDown Voltage test)

Electrical Safety Test Scanner Model 19200

  • Support Electrical Safety Test
  • Support High/Low voltage circuit insulation
  • Max.8 units for multiple scanners

Ground Bond Tester Model 19572

  • High current ground continuity testing up to 45Amps
  • Resistance measurements from 0.1mΩ up to 510mΩ
  • Compatible with the 19070 series Hi-pot Tester

Wound Component EST Analyzer Model 19036

  • 5 in 1 composite analyzer scanner (ACW/DCW/IR/IWT/DCR)
  • Hi-pot test (5kVac / 6kVdc, HSCC, 500 VA output)
  • 5kV Insulation Resistance test (IR)
  • Impulse Winding Test (IWT)